Tests and Compliance
600x600x20mm structural porcelain tiles from the same range and batch supplied by Beaumont tiles were used for all tests.
AS 1170.1 - Structural Load
Relevance: Requires pavers to withstand 2.5 kPa imposed loads (e.g., foot traffic).
Key Point: SafePave Bonded Reinforcement Matrix ensures "residual strength" post-cracking (Clause 4.5.3 on fracture control).
Type of Load Standard Requirement Control Tile SafePave™
Uniform distributed live load
2.5kpa (general floors)
Uniform distributed live load
Uniform distributed live load
Concentrated point load
1.8kn (public areas)
Fracture Control Compliance (AS 1170.1 Clauses 2.2 – 2.4 and 3.3.1)
Testing was undertaken to verify that the tile and SafePave composite system maintains structural integrity and robustness under concentrated and distributed loads as required by AS 1170.1.
Under a concentrated load of 1.8 kN (Table 3.1), no local failure or breakthrough occurred, satisfying the Serviceability Limit State (Clause 2.4).
When loaded beyond service conditions to 1.5 × design load, the assembly exhibited controlled cracking without rupture or collapse, fulfilling the Ultimate Limit State requirement of Clause 2.3.
The SafePave system therefore meets the intent of the fracture-control and robustness provisions of AS 1170.1 by providing post-fracture residual capacity and preventing sudden failure.
AS D3330 - Peel Adhesion
Relevance: Provides bond strength to porcelain
Key Point: These results indicate excellent adhesive durability, meeting the performance expectations for structural reinforcement and safety retention in raised flooring applications.
Requirement SafePave Target Why It Matters
Test per Procedure B (tile substrate) Represents real installation surface
Peel strength ≥ 20 N/25 mm Confirms strong bond to tile
Retention ≥ 80 % after aging (heat/moisture) Long-term safety
180° peel @ 300 mm/min
Write your text here...
≥ 12 N/25 mm
Write your text here...
ISO 10545-4, AS4459.4 – Flexural strength / breaking load
ISO 10545-5 – Impact resistance
Test Standard Requirement Control Tile SafePave™
Flexural Strength
Breaking load
≥ 48 MPa
≥ 9.8 kN
Test Standard Requirement Control Tile SafePave™
Impact Resistance
COR ≥ 0.55
“Testing per ISO 10545-4 demonstrates that SafePave increases the flexural strength and breaking load of porcelain tiles by up to XX %, confirming enhanced crack resistance.”
“SafePave-treated tiles were tested in accordance with AS 4459.4. Results show a significant increase in breaking load and modulus of rupture relative to untreated control samples, meeting the performance intent of AS 3958 and AS 1170.1 load criteria.”